Common questions
Can Pocket Panel change anything on my machine?
No. It only reads. It never writes, forces, downloads programs, changes modes or controls equipment.
Which devices work?
The ones in the device list. Results depend on the device and its firmware.
Why does it ask for Local Network access?
To find and read devices on your network. Without it, nothing can be found. Change it in Settings › Privacy & Security › Local Network.
No devices were found. What should I check?
Join the same network as the device and allow Local Network access. Add Device finds EtherNet/IP and BACnet/IP devices, plus nearby Siemens and OPC UA services within set limits. For anything else, enter the address. Modbus TCP also needs a port, unit ID and register profile.
A device shows as unsupported. Why?
Pocket Panel lists every device that answers, even ones it cannot read yet.
Do I need to type tag names?
Not for controllers that share their tag list. For Modbus TCP, pick a register profile or import a CSV or JSON map.
Do alarms work when the app is closed?
No. Alarms are checked only while the watchlist is open on screen. With Notify me on, you get at most one notice per alarm each minute. iOS decides when it appears.
How do I connect with Modbus TCP?
Choose Add Modbus TCP Device. Enter the IPv4 address and port (502 by default), the unit ID and a register profile. Through a gateway, use the downstream unit ID (1 to 247). Direct devices default to 255; check the device’s manual.
Pocket Panel reads coils, discrete inputs, holding registers and input registers (function codes 01–04). It never writes registers or guesses what they mean. The profile sets addresses, types, word order, scaling and units. Import UTF-8 CSV or JSON maps, and share installed profiles as JSON.
Which Modbus meter profile is included?
The only included manufacturer map is the Schneider Electric PM5560 starter profile: twelve measurements from Schneider’s published register list. It is tested in simulation; physical PM5560 and gateway qualification remain pending. Other meters need their own map.
How fast do Modbus values update?
Charts start at a requested 1 Hz. A gateway allows up to ten requests per second across all its units. A profile can set a lower limit, one update can need several requests, and slow devices lower the rate.
A missed sample stays visible as a gap, never a zero. Values are read one after another, not as one snapshot.
What does identity unavailable mean?
Some Modbus devices do not report who they are. Pocket Panel can still read them, but a profile name is not proof of the device, and a swapped device may go unnoticed.
A value says it could not be read.
Pocket Panel shows only what the device reports and says when a read fails. Refresh, or check the connection.
How do I export a recording?
Chart a value, record, stop, then share it. You get a CSV file for any spreadsheet.
How do I send a device report?
In your device list, swipe right on a saved device and tap Report. In Add Device, tap Report under a device in Other responders. Mail opens with the report attached, and nothing is sent until you tap Send. Without Mail, copy the address and tap Share File to send it another way. Review the report before you send it.
Do I need an account or internet connection?
No. Pocket Panel talks directly to your devices over your local network.
How do I share a site?
Open the site menu and choose Share Site. Show the code, or tap Send File and send it with AirDrop, Messages, Mail or Files. It never passes through a Pocket Panel server.
How do I scan a site, and why the camera?
Choose Scan to Add Site, point the camera at the code, then tap Add Site. Choose Photo reads a code someone sent you. The camera runs only while scanning and keeps no picture. Large sites show several codes in turn; scan those in Pocket Panel, not the Camera app. If the camera is off, ask for the file.
Still need help?
Email support@pocketpanelapp.com with your iOS and Pocket Panel versions, the device model and what happened. Leave out passwords and plant addresses.
Email support